BPQPT - 14838, PRO-CONTROL TOTAL RELEASE FOGGER

  • MSDS: BPQPT
  • Manufacturer: MICRO GEN EQUIPMENT CORP
  • Product Name: 14838, PRO-CONTROL TOTAL RELEASE FOGGER
  • National Stock Number: 6840-00N033956
Product Identification

Product ID:14838, PRO-CONTROL TOTAL RELEASE FOGGER
MSDS Date:04/01/1991
FSC:6840
NIIN:00N033956
MSDS Number: BPQPT

Responsible Party
MICRO-GEN EQUIPMENT CORP
10700 SENTINEL DR
SAN ANTONIO, TX 78217
US

Emergency Phone: 512-654-8570

Info Phone: 512-654-8570

Preparer: RICHARD CLARK

Cage: 52987

Contractor
MICRO-GEN EQUIPMENT CORP
SAN ANTONIO, TX 78217-3814 US

Telephone: 512-664-8570

Cage: 52987

Ingredients

PYRETHRUM; (PYRETHRIN)

CAS: 8003-34-7

RTECS: UR4200000

Fraction By Weight: 0.50%

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


TOULENE, ALPHA-(2-(2-BUTOXYETHOXY)ETHOXY)-4,

CAS: 51-03-6

RTECS: XS8050000

Fraction By Weight: 1%


5-NORBORNENE-2,3-DICARBOXIMIDE, N-(2-ETHYLHEXYL)-; (N-OCTYL

CAS: 463-04-7

RTECS: RB8575000

Fraction By Weight: 1.67%


KEROSENE (PETROLEUM), HYDROTREATED; (ISOPARAFFINIC

CAS: 64742-47-8

RTECS: OA5504000

Fraction By Weight: 10-15%


ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 55-70%

OSHA PEL 350 PPM;450 STEL

ACGIH TLV: 350 PPM;450 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PROPANE

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: <20-30%

OSHA PEL 1000 PPM

ACGIH TLV: SIMPLE ASPHYXIANT


PROPANE, 2-METHYL-; (ISOBUTANE)

CAS: 75-28-5

RTECS: TZ4300000

Fraction By Weight: <20-30%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:DIRECT CONTACT W/EYES CAN CAUSE IRRIT.
PRLNG/RPTD CONT W/SKIN MAY CAUSE ILLNESS. MAY CAUSE SEV DISTRESS &
SERIOUS ILLNESS IF TAKEN INTERNALLY. IF TAKEN INTERNALLY,
ASPIRATION OF LIQ PROD CAN CAUSE PNE UM. INHAL OF PROD VAPS MAY
CAUSE CHEM PNEUMONITIS. INHAL OF VAPS MAY CAUSE CHEM INTOXICATION @
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: HIGH AIRBORNE CONC. CHLOROCARBON
MATERIALS HAVE PRDCD SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB
ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G.,
EPINEPHRINE) MAY BE CONTRAI NDICATED EXCEPT FOR LIFE-SUSTAINING
USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. IF IRRITATION
PERSISTS, SEEK MEDICAL AID. SKIN: REMOVE WITH SOAP & WATER. INGEST:
DO NOT INDUCE VOMITING. SEEK MEDICAL AID @ ONCE. NOTES TO
PHYSICIAN: M AY PRESENT ASPIRATION HAZARD. IF DIFFICULTY OR
DISCOMFORT IN BREATHING IS EXPERIENCED, REMOVE TO FRESH AIR & GET
MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:TCC
Flash Point:20.0F,-6.7C
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:NIOSH/MSHA APPRVD PRESS DEMAND SCBA & FULL
PROT EQUIP.KEEP WETTED. FIGHT FIRE FROM MAX DIST/PROTECTED AREA.
COOL & USE CAUTION WHEN APPROACH/ (SUPP DATA)
Unusual Fire/Explosion Hazard:CONTAINER MAY BURST IN HEAT OF FIRE.
THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HCL AND PHOSGENE .

Accidental Release

Spill Release Procedures:ELIM ALL IGNIT SOURCES. DO NOT LET
SPILLED/LEAKING MATL ENTER WATERCOURSE. CONTAINS PESTICIDE, &
1,1,1-TRICHLOROETHANE. MAY BE TOXIC TO AQUATIC LIFE. ABSORB WITH
OIL-DRI OR SIMILAR INERT MATERIAL. SWE EP OR SCRAP UP AND
CONTAINERIZE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP OUT OF REACH OF CHILDREN. STORE
IN A COOL/DRY PLACE W/ADEQ VENT. DO NOT PRESSURIZE, CUT, HEAT,
WELD/EXPOSE CONTR TO FLAME; EXPLOSION COULD OCCUR.
Other Precautions:PROD RESIDUE MAY REMAIN ON/IN EMPTY CONTRS. ALL PREC
FOR HNDLG PROD MUST BE USED IN HNDLG EMPTY CONTR & RESIDUE.
CAUTION: CONTENTS UNDER PRESS. DO NOT USE NEAR HEAT/OPEN FLAME. DO
NOT PUNCT/INCIN CONT R. EXPOS TO TEMP ABOVE 120F (SUPP DATA)

Exposure Controls

Respiratory Protection:NO SPECIAL REQ WHEN LBL DIREC ARE FOLLOWED. IF
REMAINING IN ENCLSD AREAS DURING & AFTER USE, USE APPROP NIOSH/MSHA
APPRVD RESP TO PREVENT OVEREXP; ORGANIC VAPORS & PESTICIDES,
NIOSH/MSHA APPROVAL NO. TC-23C-585.
Ventilation:LOC EXHAUST, VENT BEFORE RETURNING. DO NOT REMAIN IN
ENCLOSED AREAS DURING AND AFTER USE.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMCIAL WORKERS GOGGLES .
Other Protective Equipment:USE GOOD PERSONAL HYGIENE PRACTICES. WHERE
GROSS EYE/SKIN CONT MAY BE A PROBLEM, WEAR/USE APPROP PROT EQUIP.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. LAUNDER CONTAM
EQUIPMENT BEFORE REUSE.
Supplemental Safety and Health
FIRE FIGHT PROC: HNDLG FIRE-EXPOSED CONTRS. DIKE FIRE CTL WATER FOR
LATER DISP. WASTE DISP METH: FED/ST REGS & LOC ORDINANCES. OTHER
PREC: MAY CAUSE BURSTING. NO SMOKING IN AREA OF USE. DO NOT USE IN
GEN VICIN OF ARC WELD, OPEN FLAMES/HOT SURF. HEAT &/OR UV RADIA MAY
CAUSE FORM OF HCL &/OR PHOSGENE .

Chemical Properties

HCC:V3
Spec Gravity:0.9(H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:DISPENSED AS A MIST WITH CHLORINATED SOLVENT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS (E.G. MURIATIC ACID). STRONG OXIDIZING MATERIALS (E.G.,
LIQUID CHLORINE).
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:WHEN EXPOSED TO FIRE, PRODUCES NORMAL
PRODUCTS OF COMBUSTION. MAY FORM AN ACID MIST. HCL, PHOSGENE .

Disposal

Waste Disposal Methods:PESTICIDAL WASTE: OBSERVE ALL APPLIC FED/ST REGS
& LOC ORDINANCES REGARDING DISP OF PESTICIDE WASTE. DISPOSE OF
AEROSOL CAN BY WRAPPING & PLACING IN TRASH. DO NOT PUNCT/BURN
CONTR. DISPOSE OF SPILLED RESIDUES & MULTIPLE UNITS I/A/W ALL
(SUPP DATA)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.